Abstract

The use of non-linear methods for design of slender concrete columns by European standards. For the verification of non-linear design methods it is important to compare their results with results of experiments. Within the applied research of the Faculty of Civil Engineering at Slovak University of Technology in Bratislava in cooperation with the company ZIPP Bratislava LTD the experimental verification of the slender reinforced concrete columns was realized. In the paper the authors present the preparation and process one of three series of slender reinforced concrete columns, which were made to verify the reliability of various design methods. Columns of planned second series were designed from high performance concrete C100/115, but the material tests showed that the strength class of concrete was C70/85. The columns, subjected to axial force and bending moment were designed to fail due to loss of stability before the resistance of the critical cross-section is reached. The expected compressive strain in concrete was 1,5 ‰.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.