Abstract
Energetic and exergetic analysis has been carried out for the components of the solar thermal power plant system (parabolic trough collector/receiver and Rankine heat engine). The energetic and exergetic losses as well as efficiencies for typical parabolic trough concentrating solar thermal power plant (PTCSTPP) under the specific operating conditions have been evaluated. Operating pressures for a Rankine heat engine have been optimized for maximum efficiency. It has been found that, the energetic and exergetic efficiencies of PTCSTPP increased by 1.49% and 1.51% with increasing pressure from 90 to 105 bar respectively. Progression of the STPP from the variable load to full load conditions, the year round average energetic efficiency can be increased from 22.01% to 22.62% for the location of Jodhpur, and in case of Delhi, it can be increased from 20.98% to 21.50%. Year round average exergetic efficiency can be increased, from 23.66% to 24.32% for the location of Jodhpur and in case of Delhi, it can be increased from 22.56% to 23.11%. Land areas required for the 50 MWe thermal power plants are 79.2 ha and 118.8 ha respectively for the locations of Jodhpur and Delhi.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.