Abstract
SUMMARY In this communication, a 50 MWe design capacity parabolic dish Stirling engine solar power plant (PDSSPP) has been modeled for analysis, where 2000 units of parabolic dish Stirling engine each having capacity of 25 kWe were considered to get desired capacity. An attempt has been made to carry out the energetic and exergetic analysis of different components of a solar power plant system using parabolic dish collector/receiver and Stirling engine. The energetic and exergetic losses as well as efficiencies for typical PDSSPP under the typical operating conditions have been evaluated. Variations of the efficiency of Stirling engine solar power plant at the part-load condition are considered for year-round performance evaluation. The developed model is examined at location Jodhpur (26.29°N, 73.03°E) in India. It is found that year-round energetic efficiency varies from 15.57% to 27.09%, and exergetic efficiency varies from 16.83% to 29.18%. The unit cost of electric energy generation (kWeh) is about 8.76 Indian rupees (INR), with 30 years life span of the plant and 10% interest rate on investment. Copyright © 2012 John Wiley & Sons, Ltd.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.