Abstract

By means of the fountain-convergence analysis method of FRRU (Flow Resistance-Rigidity Uniformity) index defined by the author, evidential comparison analysis study has been made to the relationship between flexible drift of flow performance of WTD (Weight Type Distributor) valves of fuel nozzles of X engine and hot-end failures of X engine. The results show that during the initial period of engine start, because of the relative scarcity of air in the combustor, a convergence characteristic, due to its converging flow property ofmultiple to one, can lead to such hot-end failures as turbine blade fusion break which is characterized byabrupt change, while a fountain characteristic, due to its diffusing flow property ofone tomultiple, cannot result in any hot-end failures.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.