Abstract

Bendamustine (BD), a volatile anti-cancer drug in Japan, was quantitatively evaluated using solid phase extraction (SPE)-type extraction device designed for the adsorption of gaseous semi-volatile organic compounds. First, the stability of BD was tested in various conditions, including solvent, temperature, and contact with oxygen. Then, the BD standard solution was spiked on filter paper, and the SPE-type extraction device was connected to the filter downstream. The filter and extraction device were then used to collect clean air. The actual volatility of BD was determined in high-performance liquid chromatography. Even after 24 h of air sampling at 7 L/min (10,080 L), the results demonstrated that BD evaporation was not confirmed. Furthermore, BD evaporation was not confirmed in a 7,000 L air sampling volume of heated air at 50°C. The volatility properties of n-alkanes of C26H54, C28H58, and C30H62 in these air sampling conditions were compared. The results show that BD is not volatile at room temperature.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.