Abstract

BackgroundProper proximal contact in direct composite restorations is crucial for periodontal health. Over a one-year period, this study was conducted to assess successive biological changes in proximal contact tightness PCT in class II direct composite restorations and the adjacent teeth by applying sectional matrix system along with different contact forming instruments.Methods72 direct compound class II composite restorations were performed in patients aged 18–40 years and divided into 4 groups: Group I (n = 18): proximal contact was restored with Palodent plus sectional matrix system, Group II (n = 18): Trimax as contact forming instrument, Group III (n = 18): Perform as contact forming instrument and Group IV (n = 18): Contact pro as contact forming instrument. All contact forming instruments were used along with Palodent plus matrix system. PCT was measured using a digital force gauge before (T0), immediate post operative (T1) and at 3 (T2), 6 (T3), 9 (T4), and 12 months (T5) after restorative treatment. Using One-Way ANOVA, Tukey’s post hoc test, and Bonferroni correction, PCT values were compared between groups before and after the intervention restoration. Meanwhile, for comparisons within groups, a paired t-test was conducted (p ≤ 0.05).ResultsContact forming instruments combined with Palodent plus sectional matrix system achieved better PCT. Trimax led to a statistically considerable tighter proximal contacts than the other groups (p < 0.05). No statistically significant difference was found in PCT between Contact pro-2, Perform and Palodent plus sectional matrix system. By means of multivariate analysis, the PCT between both T0 and T1 were increased (p < 0.001) and then it decreased till T5.ConclusionsThe use of transparent contact forming instruments achieved greater PCT compared to Palodent sectional matrix system alone that gradually decreased throughout 12 months and reached the PCT between the natural teeth. Using Trimax system provided the tightest proximal contacts. Additionally, digital force gauge was confirmed as an inclusive and accurate method to quantify PCT.Trial registrationClinicalTrials.gov NCT05749640: 24/5/2022.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.