Abstract

The evaluation of matrix cracks in carbon fiber reinforced plastics that influence the performance of the composite structure is important. This study evaluated the number of matrix cracks generated from a three-point bending test using linear and nonlinear acousto-ultrasonic detections and subsequently conducted a comparative investigation. Matrix cracks with typical width of approximately 2 μm were generated with an increase in the applied load, as confirmed by the acoustic emission detection. Three repetitions of the experiment demonstrated that the ultrasonic amplitude linearly decreased, and the second- and third-order relative nonlinearity increased in proportion to the number of matrix cracks. Subsequently, the effects of cycle number and center frequency on the ultrasonic sensitivities were discussed. The results indicated that linear detection is preferable because of its reliability and simplicity although both linear and nonlinear ultrasonic detections can be used to evaluate the matrix cracks.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.