Abstract

All camera designs for Small-Sized telescopes (SSTs) proposed for the Cherenkov Telescope Array (CTA) utilize silicon photomultipliers (SiPM) as their baseline photon sensor technology. The dual-mirror SST (SST-2M) has a smaller plate scale (i.e. image size) than the single-mirror SST, allowing it to employ 2,000 square SiPMs with pixel sizes of approximately 6 mm, close to the mainstream SiPM sizes.In CTA, the night sky background level of typically ∼25 Mcounts/s/pixel (>100 Mcounts/s/pixel at maximum) places severe constraints on the trigger capability due to accidental coincidence on neighboring pixels. In order to suppress such events, it is necessary to reduce optical crosstalk, a mechanism whereby a single optical photon can produce multiple avalanches in the SiPM, while keeping good photon detection efficiency. These are, in general, contradicting requirements.In this manuscript, we report on characterization of a variety of SiPM technologies for SST-2M cameras and compare results obtained at different participating institutions. We assess the harmonization of results and discuss the likely performance that will be achieved for the first production cameras.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.