Abstract
The major means of exposure to man-made sources of radiation is due to diagnostic examinations with X-ray. In the current research, for making practical the programs of reducing the patient's absorbed dose and increasing the quality of radiographic images in Sistan and Baluchestan hospitals, the patients surface dose and image quality were evaluated. In the first stage of experiment, the image quality and the cause of low quality of images was evaluated for a period of one month, and the patient dose for 10 adults in 7 projection were calculated in this study. Then the quality control tests were conducted to determine the equipment failures and provide appropriate corrective actions. Subsequently in the second stage of study, the image quality and patients dose were compared with the first stage of experimental data. The ESAK mean for all the centers, before and after implementing the quality control program was achieved as 0.48±0.30 and 0.37±0.20 for chest (anterior-posterior), 3.4±1.67 and 3.13±1.25 for lumbar spine (anteriorposterior), 8.81±7.72 and 7.56 ±5.99 for lumbar spine (lateral), 3.56±1.85 and 3.34±1.74 for the abdomen (anteriorposterior), 2.79±1.40 and 2.71 ±1.24 for pelvis (anterior-posterior), 2.27±1.43 and 2.1±1.25 for the skull (anteriorposterior) and 1.50±0.87 and 1.43±0.76 for the skull (lateral), respectively.(the data are based on mGy). The radiographic images quality was also increased between 0 to 10% after implementing quality control program. Results obtained show that a quality control program to reduce patient dose and increase radiographic image quality is necessary to ensure that all radiological examinations are performed under the terms of less received dose for the patients and the received images have good quality.
Highlights
Using X-rays in diagnostic radiography with expanding other modern and advanced imaging techniques is increasing day by day
Based on the concerns resulted from increasing exposure of the general public, the radiation dose levels was evaluated for the patients who are subjected to diagnostic radiography examinations as a whole in order to the patients dose be reduced as much as possible compared with the great benefits these examinations provide for the patients treatment
There are totally two concerns in the field of diagnostic radiography: The first concern related to low quality images obtained in diagnostic radiography tests which lead to wasting sources and costs, especially in developing countries
Summary
Evaluation of image quality and patient dose in conventional radiography examinations in radiology centers in Sistan and Baluchestan, Iran and comparing with that of international guidelines levels. Mohammad Javad Keikhai Farzaneh, Mahdi Shirin Shandiz, Mojtaba Vardian, Mohammad Reza Deevband and Mohammad Reza Kardan
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.