Abstract

We have proposed a stand-alone photovoltaic power system that uses electric double-layer capacitors (EDLCs) and lead acid batteries as power storage devices. We simulated the system's operating characteristics and evaluated the photovoltaic array mismatching loss, system conversion loss, battery contribution factor, averaged battery state-of-charge, and maximum depth-of-discharge. The results show that the system is effective at reducing the mismatching loss and battery contribution factor, so the system efficiency is improved. Moreover the system can maintain the averaged battery state-of-charge during operation. The maximum depth-of-discharge can be kept higher than in the conventional system. Consequently, the proposed system should have a longer battery lifetime.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.