Abstract
This study evaluated the effect of an extension ladder “walk-through” top design on kinetic and kinematic behaviors and the outward destabilizing forces induced on the ladder during transitioning at elevation. Thirty-two male participants performed stepping tasks between a ladder top and a roof at simulated elevation in a surround-screen virtual-reality system. The experimental conditions included a “walk-through” and a standard ladder top section supported on flat and sloped roof surfaces. Three force platforms were placed under the ladder section and in the roof to measure propulsion forces during transitions. A motion measurement system was used to record trunk kinematics. The frictional demand at the virtual ladder base was also calculated. The results indicate that under optimal ladder setup (angle 75.5 °), the frictional demand at the ladder base remains relatively small for all experimental conditions. Also, the “walk through” ladder top eased the ladder-to-roof transitions but not the roof-to-ladder transitions.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.