Abstract

ABSTRACTA selective coliform medium (CM), developed for the impedimetric detection of coliforms, produced better impedance signals than conventional media. The selectivity of CM was better than that of lauryl tryptose broth (LTB) and violet red bile agar (VRBA). The applicability of CM to the quantitative impedimetric detection of coliforms in meat was tested and compared with most probable number and VRBA plate counts. Approximately 90% of the typical VRBA colonies did not produce gas when tested in brilliant green bile broth (BGB). Therefore, the VRBA counts were corrected by the percentage of colonies which produced gas in BGB for each sample. A correlation coefficient of 0.90 was obtained between the impedimetric test and corrected VRBA plate counts using a combined total of 91 meat samples tested by two different laboratories.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.