Abstract

Accurately locating the hip joint center is a challenging and important step in many biomechanical investigations. The purpose of this study was to test the accuracy and robustness of a “pivoting” algorithm used to locate the hip center. We tested the performance of this algorithm with data acquired by manipulating a ball and socket model of the hip through several motion patterns. The smallest mean errors of 2.2±0.2 mm occurred with a circumduction motion pattern, while the largest errors of 4.2±1.3 mm occurred with single-plane motion (e.g., flexion/extension). Introducing random noise with an amplitude of 30 mm increased the errors by only 1.3±0.5 mm with a circumduction motion pattern. The pivoting algorithm performs well in the laboratory, and further work is warranted to evaluate its performance in a clinical setting.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.