Abstract

This paper evaluates the biofidelity of the Hybrid Ill 5th percentile female dummy relative to seven small female cadavers tested as out-of-position drivers in static air bag deployment tests. In the out-of-position tests, the chest was positioned against the air bag module in an effort to recreate a worst-case loading environment for the thorax. Two pre-depowered production air bags and a prototype dual-stage air bag were evaluated. Thoracic accelerometers and chestbands were used to compare chest compression, velocity, acceleration, and Viscous Criteria. A statistical comparison of dummy and cadaver results indicate acceptable biofidelity of the Hybrid Ill dummy with significant differences observed only in the Viscous Criteria. (A) For the covering abstract of the conference see IRRD 492347.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.