Abstract

Semi-dry FGD with fabric filter has been extensively studied in recent years. After a series of industrial tests on 300MW boiler with semi-dry FGD and fabric filter, some operation notes were obtained. The test results show that CFB-FGD with fabric filter can be run longer and stable, and its actual performance is even higher than the design parameters. Moreover, the pressure drop of fabric filter after CFB-FGD is 600~800Pa (higher than normal). The fabric filter, which contributes to the desulfurization efficiency of the whole system about 5%, increasing the cleaning period, is benefit to the desulfurization efficiency, and the operation environment of fabric filter is that the relative humidity (RH) is below 30% or the flue gas temperature is 20oC higher than the dew point (DP).

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.