The paper deals with the tray-to-tray method for determining the required number of trays in columns with intensive entrainment of liquid when the operating line of the “dry working regime” is not straight and with a small concentration of diffusing component in gas. Presented calculations show that the number of transfer units for gas and liquid should be calculated using the AIChE method accompanied with longitudinal mixing according to Gilbert properly transformed for case of diffusion through stagnant film. The suggested method can be applied for TEG dehydration absorbers–columns for dehydration of natural gas using triethylene glycol with system factor SF = 0.5.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.