Abstract

In the present study, the thermal endurance of epoxy-based, bismaleimides, and cyanate ester resins for the current design of the in-vessel coils was measured by performing acceleration tests to assess their insulation properties using the thermal endurance defined by the International Electrotechnical Commission (IEC-60216 Part1–Part 6) for a minimum of 5,000h in the 180–240°C temperature range. It was found that none of the resin insulators could tolerate the baking conditions of 40,000h at ∼200°C in the JT-60SA vacuum vessel. Therefore, the design of the in-vessel coils, including the error field correction coils (EFCC), was changed from the type without water cooling to with water cooling on JT-60SA.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.