Abstract

The main purpose of this study was to determine local diagnostic reference level (LDRL) for routine computed tomography (CT) examination in Bafoussam, western Cameroon. The exposure parameters and dose quantities were collected manually. This retrospective, evaluative and comparative study was conducted to determine LDRLs for routine head CT examination in Bafoussam, to optimize these procedures in the region. The 75th percentile values of the calculated volume CT dose index (CTDIvol) and dose length product (DLP) were proposed as LDRL. The sample was classified in four age groups: < 1, 1-5, 5-10 and 10-15y. The LDRLs obtained for the four age groups were: 24mGy and 381.32mGy.cm, 42.5mGy and 875.55mGy.cm, 45.85mGy and 939.62mGy.cm, 57.12mGy and 1222.3mGy.cm, respectively. The 75th percentile CTDIvol and DLP dose values for this study are higher than international values. We propose a coordinating discussions and collaboration about patient's and specific equipment's change information's, between radiologists, medical imaging technicians and medical physicist, which can reduce absorbed doses and improved medical practice in hospitals.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.