Abstract

The causes of fluctuations of the acoustic-impulse propagation velocity in a composite plate upon a change in the distance between the radiation source and a receiving transducer from 30 to 300 mm were studied. Methods for minimizing these fluctuations by reducing the influence of high-frequency wave-packet modes at the time of recording impulses by acoustic-emission transducers were developed. The use of the latter in determining the propagation velocity of a wave packet contributed to a decrease in fluctuations and stabilization of measurements in the diagnostic zones of the composite plate. These methods made it possible to reduce the velocity fluctuations by more than 30% compared to the standard calculation method.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.