Abstract

In this paper, a new radiation detection method is introduced which uses a commercial gel material for the measurement of radon ( 2 2 2 Rn) gas. This method is based on the diffusion of radon gas into the gel material and the measurement of the radioactive daughters resulting from the radon decay. The 2 1 4 Bi daughter gamma-ray, with an energy of 0.609 MeV, was chosen for these measurements, and the gamma-ray photopeak was analyzed via a HPGe multichannel system. The results indicate a linear relationship between the integrated area of the 2 1 4 Bi photopeak and the concentration of radon that had diffused into the gel material. Two very well defined radon response levels were observed: (1) from 150 to 1500 Bq.m - 3 and (2) from 1500 to 7400 Bq.m - 3 . This method gives highly reproducible and reliable results in the measurements of radon. This new technique opens the door to future studies of different gel materials in order to obtain better sensitivity and new applications in the measurement of radioactive gases.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.