Abstract

Electromagnetic interference shielding has attracted attention in design processes for reducing radiation to protect humans or equipment. Traditional shielding constitutes adding strengthening, conductive paints, conductive fibers, or grids to non-damaged structures. Few studies have considered using hybrid reinforcement methods for shielding effectiveness or examined the relationship between damaged areas and shielding effectiveness. We prepared a reinforced concrete (RC) wall with different steel fiber contents, metallic grid/mesh reinforcement, and hybrid reinforcement and created damage areas via impact load. Compared with 300 mm thick RC and single-type reinforced specimens, the hybrid reinforced specimens had an approximately 25.9 times and 2.4 times higher shielding effectiveness, respectively. Specimens reinforced with metallic mesh exhibited less than 150% of free space area ratio and more than 30 dB shielding effectiveness. The hybrid metallic mesh and facultative metallic grid achieved over 40 dB. Hybrid reinforced specimens exhibited improved impact resistance and great shielding effectiveness in damaged conditions.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.