Abstract

BackgroundThe AGuIX® (NH TherAguix) nanoparticle has been developed to enhance radiotherapy treatment and provide strong MR contrast. These two properties have previously been investigated separately and progressed to clinical trial following a clinical workflow of separate MR imaging followed some time later by radiotherapy treatment. The recent development of MRI-linacs (combined Magnetic Resonance Imaging–linear accelerator systems enabling MRI-guided radiotherapy) opens up a new workflow where MR confirmation of nanoparticle uptake can be carried out at the time of treatment. A preclinical study was carried out to assess the suitability of a gadolinium-containing nanoparticle AGuIX® (NH TherAguix) for nano-enhanced image-guided radiotherapy on an MRI-linac.MethodsTreatments were carried out on F344 Fischer rats bearing a 9L glioma brain tumour. Animals received either: (A) no treatment; (B) injection of nanoparticles followed by MRI; (C) radiotherapy with MRI; or (D) injection of nanoparticles followed by radiotherapy with MRI. Pre-clinical irradiations were carried out on the 1.0 T, 6 MV in-line Australian MRI-linac. Imaging used a custom head coil specially designed to minimise interference from the radiotherapy beam. Anaesthetised rats were not restrained during treatment but were monitored with a cine-MRI sequence. Inductively Coupled Plasma Mass Spectrometry (ICP-MS) analysis was used to quantify residual gadolinium in the brain in normal and tumour tissue.ResultsA preclinical evaluation of nano-enhanced radiation treatment has been carried out on a 1.0 T MRI-linac, establishing a workflow on these novel systems. Extension of life when combining radiotherapy with nanoparticles was not statistically different from that for rats receiving radiotherapy only. However, there was no detrimental effect for animals receiving nanoparticles and radiation treatment in the magnetic field compared with control branches. Cine-MR imaging was sufficient to carry out monitoring of anaesthetised animals during treatment. AGuIX nanoparticles demonstrated good positive contrast on the MRI-linac system allowing confirmation of tumour extent and nanoparticle uptake at the time of treatment.ConclusionsNovel nano-enhanced radiotherapy with gadolinium-containing nanoparticles is ideally suited for implementation on an MRI-linac, allowing a workflow with time-of-treatment imaging. Live irradiations using this treatment workflow, carried out for the first time at the Australian MRI-linac, confirm the safety and feasibility of performing MRI-guided radiotherapy with AGuIX® nanoparticles. Follow-up studies are needed to demonstrate on an MRI-linac the radiation enhancement effects previously shown with conventional radiotherapy.

Highlights

  • The ­AGuIX® (NH TherAguix) nanoparticle has been developed to enhance radiotherapy treatment and provide strong MR contrast

  • The results demonstrate that the technique is safe to deliver in the presence of a magnetic field with the administration of nanoparticles combined with MRI causing no significant change to survival post-treatment

  • Nano-enhanced radiotherapy using a gadolinium-based nanoparticle such as AGuIX is ideally suited for implementation on new MRI-linac systems due to the superior accuracy of determining nanoparticle uptake at time of treatment

Read more

Summary

Introduction

The ­AGuIX® (NH TherAguix) nanoparticle has been developed to enhance radiotherapy treatment and provide strong MR contrast. The recent development of MRI-linacs (combined Magnetic Resonance Imaging–linear accelerator systems enabling MRI-guided radiotherapy) opens up a new workflow where MR confirmation of nanoparticle uptake can be carried out at the time of treatment. There are currently four types of MRI-linac systems worldwide (Liney et al 2018b) with increasing adoption in the clinic of the two leading commercial offerings: the ViewRay MRIdian with a 0.35 T magnet (Klüter 2019) and the Elekta Unity with a 1.5 T magnet (Raaymakers et al 2017) Both systems introduce the patient parallel to the magnetic field direction along the bore of the magnet, with a split magnet design leaving a gap for the radiotherapy beam to be delivered perpendicular to the magnetic field. These are the Australian MRIlinac (Keall et al 2014) and the Aurora-RT from MagnetTx (Fallone 2014)

Methods
Results
Discussion
Conclusion
Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.