Abstract

To estimate the level of radiation exposure of personnel handling diagnostic X-ray machines, the yield of chromosomal aberrations was analysed in peripheral blood lymphocyte cultures. These occupationally exposed individuals showed higher frequencies of dicentrics as well as acentrics than normal controls. Absorbed radiation doses calculated by extrapolating reference in vitro dose-response curve for dicentrics ranged between 0.13 and 0.17 Gy. This implies exposure beyond the permissible limit of 0.05 Gy/year for the whole body. However, no obvious trend of increased aberrations as a function of either duration of employment or age was noticed. The increase in the aberration yields in this personnel underscores the need of adopting measures to avoid or minimise such overexposure.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.