Abstract

An invessel neutron monitor using micro-fission chambers is one of the most important diagnostics to measure the fusion power in ITER. A single micro-fission chamber with 10 mg of 235U to be installed in a gap between a shielding blanket module and a vacuum vessel can cover the range of the fusion power from 100 kW to 1 GW. For the low fusion power operation including D–D operation, a micro-fission chamber bundle consisting of 13 micro-fission chamber units has been designed. Nuclear heating of the micro-fission chamber for high power operations and the micro-fission chamber bundle for low power operation were analyzed by neutron transport calculations using the MCNPX code. Heat transport analyzes for the micro-fission chambers were carried out with a general purpose Finite Element Method code ANSYS 8.1, which indicated that the detector temperature might be kept less than the operational temperature limit by the thermal conduction to the vacuum vessel with the heat transfer coefficient of 100 W/m 2 K or larger.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.