Abstract

A fixed frequency RF accelerating resonator has been built and tested for the Fermilab Energy Saver. Table I shows the design parameters and prototype resonator test results. The resonator features a high permeability nickel alloy resistor which damps unwanted modes and corona rolls designed with the aid of the computer code SUPERFISH. In bench measurements, the prototype resonator has achieved peak accelerating voltages of 500 kV for a 1% duty cycle and CW operation at 360 kV. The prototype has also been successfully operated with beam in the FNAL Main Ring.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.