Abstract

Application of energy efficient compressors, air handling units (AHUs), condensers and evaporators of high effectiveness are the some of the measures towards energy conservation in refrigeration systems. Cooling of compressor shell with the defrost drips is an energy saving measure which is explored in this paper. In tropical countries which have 70–80% RH year round, the quantity of defrost formation is significant while refrigeration systems are on. This defrost water is dripped on the compressor's shell, which in turn cools the compressor oil and hence reduces the friction losses and winding temperature of the motor. Once winding temperature is reduced the compressor's ampere rating is reduced which ultimately reduces the energy consumption of the compressor. For given conditions of refrigerator function, the compressor shell temperature and ampere rating of compressor are tabulated and investigated before and after compressor shell cooling. The investigation reveals that around 8–10% energy savings are achieved for the given conditions.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.