Abstract

In this work, the applicability of ICG-VA to skull base endoscopic surgery and its capacity to locate the internal carotid artery are shown. An adapted optical module to perform ICG-VA was used to perform endoscopic procedures. There were two intraoperative phases of interest that were used to evaluate the ICA: upon exposure of the skull base and during the intradural exploration. This new tool for obtaining ICA images in real time (as opposed to with navigation), and it is demonstrated that this tool provides a superior ability to detect the margins of the ICA compared with the Doppler technique. On the other hand, the present technique also provides enhancement of the artery through the bone of the skull base without the need for drilling. ICG-VA is a safe and effective technique for locating the ICA in skull-base expanded endonasal surgery. Furthermore, this technique can provide real-time guidance for the surgeon and increase safety for the patient.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.