Abstract

The measurement and calculation of end winding deformations for different turbo generators is presented. The measurements have been realized on three turbo generators of ratings from 94 MVA to 550 MVA. They have been done both for full load operation and for a three phase short circuit and were compared with calculation results. The nonlinearity and the influence of temperature on amplitudes and frequencies of the deformations is investigated.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.