Abstract

Abstract Combustion tests have been performed in a 500 kW pulverized coal furnace in order to investigate the cofiring characteristics of torrefied spruce and bituminous coal (El Cerrejon coal from Colombia). Monocombustion test cases for the coal and torrefied spruce were also performed for a comparative evaluation. Measurements performed include burn-out, gas temperature profiles and emissions characteristics (CO, NOX, SO2 and HCl). Combustion behavior was evaluated for all cases via measurement of the spatial distribution of oxygen across the flame and at the active combustion zones within the furnace. The impact of air staging on NOX reduction was investigated at two different primary or burner stoichiometric ratios for all fuels, while operational issues such as deposit formation and characteristics were also evaluated. The experimental study demonstrates the operational feasibility of cofiring at higher shares while also showing that emissions such as NOX and SOX can be reduced just by cofiring. Air-staging will even further reduce NOX emissions while smart fuel mixing will ameliorate operational issues related to ash characteristics such as slagging.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.