Pre-dried sewage sludge with high sulfur content was combusted in an electrically heated lab-scale fluidized-bed incinerator. The emission characteristics of polychlorinated dibenzo-p-dioxins (PCDDs), polychlorinated dibenzofurans (PCDFs) and polycyclic aromatic hydrocarbons (PAHs) were studied. Coal and calcium oxide (CaO) were added during the sewage sludge combustion tests to optimize combustion conditions and control SO2 emission. The results indicated that the flue gases emitted during mono-combustion of sewage sludge were characterized by relatively high concentrations of SO2, NOx and organic pollutants, due to the high sulfur, nitrogen, and volatile matter content of sewage sludge. The total 16 USEPA priority PAHs and 2,3,7,8-substituted PCDD/Fs produced from sewage sludge combustion were found to be 106.14 microg/m3 and 8955.93 pg/m3 in the flue gas, respectively. In the case of co-combustion with coal (m(sludge)/m(coal) = 1:1), the 16 PAHs and 2,3,7,8-substituted PCDD/Fs concentrations were markedly lower than those found during mono-combustion of sewage sludge. During co-combustion, a suppressant effect of CaO on PCDD/Fs formation was observed.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.