AbstractA recent runaway reaction emergency relief system design includes a passive quench tank to collect and contain the two‐phase emergency relief discharge. This avoids the release of a large vapor cloud to the atmosphere and the attendant flammability and toxicity hazards. The feasibility of quenching is demonstrated with small scale experiments. A pressure relief simulation model is shown to accurately reproduce the observed temperature and pressure profiles in both the reactor and quench tank during relief. The model is then applied to the design of a full scale system. Quench system design considerations are discussed.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.