Abstract

Simulated loss of coolant accident (LOCA) tests on Zircaloy-4 cladding were carried out to evaluate the thermal shock property during the injection of emergency core coolant. A Zircaloy-4 specimen was oxidized in a steam environment between 1000 and 1250°C followed by a flooding of the cooling water. After the test, the ductility of the thermally embrittled specimen was measured by a ring-compression test and a microstructural analysis was carried out. The results showed that the threshold equivalent cladding reacted (ECR) value to cause a failure was higher than the conventional 17% criterion calculated by the Baker–Just equation. A residual metal thickness under 0.3mm as well as a ring-compression ductility below 0.2mm for a fracture is effective to assess the thermal shock embrittlement of Zircaloy-4 in an axially unrestrained, or even in a restrained condition.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.