Abstract

Totally implanted port devices play an important role in acute and chronic medical care of patients with various conditions and are widely used for infusion of fluids, medications, blood or other blood products, and for monitoring hemodynamic parameters. Embolization of a part of port devices is a rare but potentially serious complication of port catheter placement. We report distal embolization of a catheter fragment of a PORT-A-CATH device into the main pulmonary artery and right ventricle and its successful percutaneous retrieval in a patient with metastatic lung cancer, who was also found to have thoracic inlet syndrome or pinch-off syndrome.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.