Abstract
Abstract The effects of processing parameters, including solution concentration, viscosity, nozzle diameter, voltage bias and the nozzle to collector distance, on the morphology and diameters of poly(methyl methacrylate) (PMMA) fibers have been systematically investigated, using a unique pump-free electrospinning method. For PMMA solution concentrations less than the critical entanglement concentration, ce, prolate spheroid-shaped droplets or beads with fibers were formed, whereas at concentrations above ce, good quality bead-free fibers were formed. Quantitative analysis revealed a linear dependence between the solution viscosity and fiber diameter. Larger fiber diameters were achieved by increasing the nozzle diameter and voltage bias. Increasing the bias voltage has the additional effect of broadening the diameter distribution, as a result of splaying and splitting. By contrast, when the strength of the electrical field was reduced by increasing the distance between the nozzle and collector, the overall fiber diameter was reduced.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.