Abstract
An anatomically based 5628-cell model of a human being was used to calculate local, layer-averaged, and whole-body-averaged specific absorption rates and internal RF currents at 27.12 and 40.68 MHz for spatially variable electromagnetic fields of a parallel-plate applicator representative of RF dielectric heaters used in industry. The conditions of exposure of the man model considered are: isolated from ground, shoe-wearing condition, feet in contact with ground, and an additional grounded top plate 13.1 cm above the head to simulate screen rooms that are occasionally used for RF heaters. Since peak E fields as high as 1000-2700 V/m have been measured at locations typically occupied by the operator, significant internal RF currents on the order of 0.5-2.3 A are projected for the operators. Measurements of the foot currents at 27.12 and 40.68 MHz for a human subject are in reasonable agreement with the calculated values for the various conditions of exposure.< <ETX xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">></ETX>
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
More From: IEEE Transactions on Microwave Theory and Techniques
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.