Electrochemical treatment of two health-care wastewaters – A comparative study

  • Abstract
  • Literature Map
  • Similar Papers
Abstract
Translate article icon Translate Article Star icon

ABSTRACT Organics removal from health-care wastewaters (HCWWs) is of prime concern worldwide. Water reclamation along with treatment using electrochemical technique was achieved in the present research. Partial mineralization was achieved using two-dimensional (2D) iron electrodes for cell voltages of 3, 6, 9, 12, and 15 V for an electrolysis time (ET) of 60 min for a fixed SA/V specific electrode area to a volume of 40 m2m−3. The maximum COD and TDS removal of 88.4% and 58.44% was obtained for Government HCWW compared to private HCWW of 79.5% and 50.6%, respectively, at 12 V for 60 min ET. ECC experiments were also carried out for discrete ETs for optimized 12 V cell voltage. Along with COD and TDS, other quality parameters were also analyzed after 1 h hydraulic retention time (HRT). After ECC, total alkalinity, chloride, and total solids significantly reduced from their initial values. ECC showed good disinfection potential by lysing pathogens in HCWWs at 45–60 min ET. Post ECC slurry for both HCWWs showed good filterability. The current efficiency (CE) was 200–220% and specific energy consumption (SEC) was 25–80 kWh/kg of COD removed for 45–60 min ET. Water reclamation of 80–85% was possible after settling, followed by filterability of treated supernatant for both HCWWs.

Similar Papers
  • Research Article
  • Cite Count Icon 11
  • 10.1016/j.jwpe.2018.10.009
Treatment of healthcare facility wastewaters by two dimensional (2D) electrochemical coagulation (ECC), settling and filterability aspects
  • Nov 1, 2018
  • Journal of Water Process Engineering
  • Sujit Singh + 3 more

Treatment of healthcare facility wastewaters by two dimensional (2D) electrochemical coagulation (ECC), settling and filterability aspects

  • Research Article
  • Cite Count Icon 69
  • 10.1016/j.scitotenv.2018.03.346
Enhanced performance and microbial community analysis of bioelectrochemical system integrated with bio-contact oxidation reactor for treatment of wastewater containing azo dye
  • Apr 7, 2018
  • Science of The Total Environment
  • Youzhao Wang + 7 more

Enhanced performance and microbial community analysis of bioelectrochemical system integrated with bio-contact oxidation reactor for treatment of wastewater containing azo dye

  • Research Article
  • Cite Count Icon 27
  • 10.1016/j.biortech.2020.123928
Using multiple carbon brush cathode in a novel tubular photosynthetic microbial fuel cell for enhancing bioenergy generation and advanced wastewater treatment
  • Jul 29, 2020
  • Bioresource Technology
  • Hai T.H Nguyen + 1 more

Using multiple carbon brush cathode in a novel tubular photosynthetic microbial fuel cell for enhancing bioenergy generation and advanced wastewater treatment

  • Research Article
  • Cite Count Icon 80
  • 10.1007/s11356-016-7139-6
Optimizing COD removal from greywater by photoelectro-persulfate process using Box-Behnken design: assessment of effluent quality and electrical energy consumption.
  • Jul 2, 2016
  • Environmental Science and Pollution Research
  • Mehdi Ahmadi + 1 more

Greywater (GW) is a potential source for water reuse in various applications. However, GW treatment is still a vital issue in water reuse in cases of environmental standards and risk to public health. This study investigates optimization and modeling of a hybrid process for COD removal from GW. Persulfate (PS) was simultaneously activated by electrogenerated ferrous ion (EC) and UV to generate sulfate radical. Photoelectro-persulfate (PEPS) was optimized by Box-Behnken design and the effects of four variables (pH, PS dosage, current density, and electrolysis time) were evaluated on COD removal. The results and several coefficients showed that the obtained model was acceptable for predicting the COD removal. Moreover, under optimum conditions (pH=6.9, PS=8.8mM, current density=2.0mA/cm(2), and 49.3min electrolysis time), BOD5, turbidity, TSS, phosphate, and UV254 were effectively removed and COD and BOD5 values reached to discharge standards. Different configurations of the processes were assessed for COD removal. The order of COD removal efficiency followed: PS < Fe(II) < UV/PS ≤ Fe(II)/PS < Fe(II)/PS/UV < electrocoagulation ≤ electrocoagulation/UV < electro-PS < PEPS. The monitoring PS concentration during 60min reaction time in the aforesaid processes indicated that PEPS could remarkably activate PS. The solution pH was also monitored and related results revealed that the presence of PS during the 10min first time decreased pH value while production of hydroxide ion at cathode increased pH significantly. Finally, the contribution of electrochemical process in the electrical energy consumption was far less than that of photolysis process in hybrid PEPS process.

  • Research Article
  • Cite Count Icon 11
  • 10.1007/s11270-016-3165-8
Removal Performance, Antibacterial Effects, and Toxicity Assessment of Ciprofloxacin Treated by the Electrocoagulation Process
  • Nov 25, 2016
  • Water, Air, &amp; Soil Pollution
  • Fernando R Espinoza-Quiñones + 6 more

This study is concerned with the removal performance of the antibiotic ciprofloxacin (CIP) from synthetic solutions by electrocoagulation (EC), as well as the toxic effects of treated CIP solutions. A response surface analysis (RSA) was applied to search optimal operational parameter values of the pH of solution, electrical current density (ECD), and electrolysis time (ET). The EC efficiency was evaluated by determining the total organic carbon (TOC) and CIP concentration performed by high-performance liquid chromatography. Although the best EC efficiency was attained at pH = 8, ECD = 22.2 A m−2, and ET = 75 min, toxicity and antibacterial tests were performed using Artemia salina cysts and Staphylococcus aureus and Escherichia coli microorganisms in a wide ET range and other pH and ECD values. Increasing optimal pH value (9), along with reducing optimal ECD value (18 A m−2) and regarding low ET values, similar results for the removal of CIP (98%) and TOC (87%) were also attained. Toxicity variation was observed during EC process in synthetic solutions with the lowest antibacterial effects due to CIP and recalcitrant compound residues after 40 min of ET. These results clearly showed that the EC process presents a promising alternative method for the treatment of wastewaters containing high CIP concentrations.

  • Research Article
  • Cite Count Icon 42
  • 10.1016/j.cep.2022.109127
Electrochemical oxidation of direct blue 86 dye using MMO coated Ti anode: modelling, kinetics and degradation pathway
  • Aug 31, 2022
  • Chemical Engineering and Processing - Process Intensification
  • Diwakar Kumar + 1 more

Electrochemical oxidation of direct blue 86 dye using MMO coated Ti anode: modelling, kinetics and degradation pathway

  • Research Article
  • Cite Count Icon 34
  • 10.1016/j.jece.2013.06.021
Studies on various mode of electrochemical reactor operation for the treatment of distillery effluent
  • Jul 4, 2013
  • Journal of Environmental Chemical Engineering
  • Modepalli Susree + 3 more

Studies on various mode of electrochemical reactor operation for the treatment of distillery effluent

  • Research Article
  • Cite Count Icon 93
  • 10.1016/j.cej.2010.07.057
Treatment of textile dyeing wastewater using two-phase pilot plant UASB reactor with sago wastewater as co-substrate
  • Aug 3, 2010
  • Chemical Engineering Journal
  • M Senthilkumar + 3 more

Treatment of textile dyeing wastewater using two-phase pilot plant UASB reactor with sago wastewater as co-substrate

  • Research Article
  • Cite Count Icon 53
  • 10.1016/j.cej.2014.12.048
Treatment of volatile organic compounds in pharmaceutical wastewater using submerged aerated biological filter
  • Dec 24, 2014
  • Chemical Engineering Journal
  • V.S Priya + 1 more

Treatment of volatile organic compounds in pharmaceutical wastewater using submerged aerated biological filter

  • Research Article
  • Cite Count Icon 79
  • 10.1016/j.apenergy.2017.10.026
Energy recovery evaluation in an up flow microbial electrolysis coupled anaerobic digestion (ME-AD) reactor: Role of electrode positions and hydraulic retention times
  • Oct 10, 2017
  • Applied Energy
  • Thangavel Sangeetha + 7 more

Energy recovery evaluation in an up flow microbial electrolysis coupled anaerobic digestion (ME-AD) reactor: Role of electrode positions and hydraulic retention times

  • Research Article
  • Cite Count Icon 15
  • 10.1007/s10098-012-0506-1
Comparative performance of anaerobic reactors for treatment of sago industry wastewater
  • Jun 30, 2012
  • Clean Technologies and Environmental Policy
  • P Doraisamy + 3 more

For a country like India where energy continues to be precious, with oil prices continuing to rise unlike in the West, anaerobic digestion has far greater relevance than it has to many other regions of the world. The cassava starch production in our country is mainly concentrated in small to medium scale factories, which generates 30,000–40,000 l of effluent per ton of sago produced. The effluent is acidic and highly organic in nature having chemical oxygen demand (COD) of 5,000–7,000 mg l−1 during the season and 1,000–5,000 during the off-season. These effluents pose a serious threat to the environment and quality of life in the rural area. Since the treatment of cassava starch factory effluents through the normal biogas plants with 30–55 days retention period is very costly, attempts have been made to treat them through high-rate hybrid reactor with several hours of retention period. In Random-Packed Anaerobic Filter, the maximum COD reduction was observed (84.4 %) at 10 h hydraulic retention time (HRT). At 4 h HRT only 46.3 % COD was removed. Even though higher COD removal was achieved at 20 h, the better HRT was at 10 h as the difference between the 20 and 10 h HRT in only 0.2 %. In Up-flow Anaerobic Sludge Blanket reactor, the maximum COD removal (90 %) and total solid (TS) removal (82 %) were observed in a HRT of 30 h, whereas low COD (67 %) and TSs (64 %) removal was observed at 5 h HRT. The treatment of sago industry effluent in a hybrid reactor was studied and the HRT employed was 10, 24, 32, and 40 h. The COD removal rates were 86, 93, 94, and 95 %, and the TSs removal was 79, 85, 86, and 89 %. When the results of all these three reactors were compared, the hybrid reactor seems to be better with an optimum HRT range of 10–20 h. Hence, the anaerobic digestion has proved to be an effective method of treating the sago industry wastewater with simultaneous production of energy in the form of methane.

  • Research Article
  • Cite Count Icon 1
  • 10.1088/1755-1315/356/1/012014
Study on Preparation Conditions of Electrolyzed Reduced Alkaline Water
  • Oct 1, 2019
  • IOP Conference Series: Earth and Environmental Science
  • Liuxin Jing + 2 more

In this study, the preparation conditions (electrolytic voltage, electrode interval and electrolysis time) of electrolyzed reduced alkaline water were optimized. Results show that electrolytic time, electrolytic voltage and electrode interval could influence the water quality of the electrolyzed reduced alkaline water. More electrolysis time, higher of electrolytic voltage, and smaller electrode interval resulted in higher water pH value. More electrolysis time, higher electrolytic voltage, and larger electrode interval resulted in lower water ORP value. The optimum condition for preparation of weak alkaline primary water is 10v electrolytic voltage, 15 mm interval of electrodes and 2 min electrolysis time.

  • Research Article
  • Cite Count Icon 5
  • 10.2166/wst.2016.619
Optimization of copper removal from aqueous solutions in a continuous electrochemical cell divided by cellulosic separator.
  • Dec 28, 2016
  • Water science and technology : a journal of the International Association on Water Pollution Research
  • Ali Asghar Najafpoor + 2 more

Copper, as an inseparable part of many industrial discharges, threatens both public and environmental health. In this work, an electrochemical cell utilizing a cellulosic separator was used to evaluate Cu removal using graphite anodes and stainless steel cathodes in a continuous-flow mode reactor. In the experimental matrix, Cu concentration (1-5 mg L-1), electrolysis time (20-90 min), and current intensity (0.1-0.4 A) were employed. Results showed that the maximum removal efficiency of copper was obtained as 99%. The removal efficiency was independent of initial copper concentration and directly related to electrolysis time and current intensity. Energy consumption was more dependent on current intensity than electrolysis time. Under optimal conditions (75.8 min electrolysis time, 0.18 A current intensity, and 3 mg L-1 copper concentration), the removal efficiency was obtained as 91% while 7.05 kWh m-3 electrical energy was consumed. The differences between the actual and predicted data under optimal conditions were 0.42% for copper removal and 0.23% for energy consumption, which signify the performance and reliability of the developed models. The results exhibited the suitability of the electrochemical reduction for copper removal from aqueous solutions, which was facilitated under alkaline conditions prevailing in the cathodic compartment due to applying a cell divided by a cellulosic separator.

  • Research Article
  • Cite Count Icon 7
  • 10.21608/ejchem.2018.4128.1361
Membrane Bioreactor Technology for Wastewater Reclamation
  • Jul 12, 2018
  • Egyptian Journal of Chemistry
  • Aly Alaneny + 4 more

Responding to the water shortage in Egypt, the use of submerged membrane bioreactor (SMBR) for wastewater reclamation has been studied. The impact of hydraulic retention time (HRT), as the most influential operational parameter has been investigated. A bench-scale module was operated at three HRT: 6, 10 &15hs. The results demonstrated that total COD and BOD removal rates were not affected by changing the HRT or by variations in raw wastewater strength. Average residual COD values in the membrane permeate ranged from 14 to 20.3 mg O2 L-1. Corresponding residual BOD was below 3.0 mgL-1. Nitrification capacity of the SMBR was high. HRT was found to be a key parameter for fouling. Decreasing the HRT enhances membrane fouling. At HRT of 6h, fouling happened after 6 days. Corresponding values for HRTs 10 and 15 were 13 day and more than 42 days, respectively. Total coliform bacteria counts in most of the MBR permeate samples were below the detection limit of 10 CFU/100 mL. All protozoan parasitic stages detected in raw wastewater were removed by the SMBR. At HRT of 15h, both human rotaviruses and adenoviruses genome copies were reduced by 2 to 3 log10. This ratio was reduced by decreasing the HRT.

  • Research Article
  • Cite Count Icon 43
  • 10.1016/j.biortech.2008.10.049
Effects of nitrobenzene concentration and hydraulic retention time on the treatment of nitrobenzene in sequential anaerobic baffled reactor (ABR)/continuously stirred tank reactor (CSTR) system
  • Dec 6, 2008
  • Bioresource Technology
  • O Kuscu + 1 more

Effects of nitrobenzene concentration and hydraulic retention time on the treatment of nitrobenzene in sequential anaerobic baffled reactor (ABR)/continuously stirred tank reactor (CSTR) system

Save Icon
Up Arrow
Open/Close