Abstract

Graphite-like carbon electrodes produced from the University of Idaho thermolyzed asphalt reaction (GUITAR) were examined for anodic sensing of chemical oxygen demand (COD). For maximum sensitivity the surfaces were modified with quinone functionality (q-GUITAR). Analysis by FT-IR indicated C-OH and CO groups on the surface which was verified by and X-ray photoelectron spectroscopies (XPS). The capacitance as measured by cyclic voltammetry (CV) of q-GUITAR is 170 times greater in 1.0 M H2SO4 than the pristine material indicating a more hydrophilic surface. This enhances the anodic oxidations of the COD surrogates consisting of glucose, potassium hydrogen phthalate (KHP), lactic acid, and sodium dodecyl benzenesulfonate (SDBS). At a constant potential of 1.6 V vs. Ag/AgCl q-GUITAR anodes have the largest linear range of 0 to 10,000 ppm (as glucose) reported in literature. The limit of detection (40 ppm) and sensitivity are competitive with other electrode systems.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.