Abstract

In the present work, we describe the electrochemical behaviour of two opioids structurally related to aroyl amides of forensic interest, namely U-47700 and AH-7921. The data obtained allowed for the mise-au-point of a voltammetric determination protocol, that relies on differential pulse voltammetry (DPV) at a glassy carbon electrode in ethanol/0.1 M lithium perchlorate/0.10 M 2,6-lutidine. To apply the method to the analysis of real samples (urines), a clean-up and a preconcentration strategy by solid phase extraction (SPE) using the adsorbent Florisil have been developed. LOQ of 0.2 μg·mL−1 in urine samples with an enrichment factor of 20 and linear range from 5 to 150 μg·mL−1 were obtained.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.