Abstract

A critical issue in electrical tomography is ill-posed problems due to low sensitivity. In the electric current injection method, the placement of the injection electrode on the object boundary can influence it. This condition causes the reconstruction result of parameter change far away from the boundary to be inferior in quality. Another excitation method is using magnetic field induction proposed to overcome these problems. Each reconstruction image was obtained using two methods with three types of parameter changes, that represented the edge and the center of the object position. Both reconstruction results are merged and further processed to enhance the quality of the image, based on the average value of the resistivity of each element. The results show that the final image reconstruction has a smaller root mean square error (RMSE) than the electric current injection method.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.