Abstract

Setting the optimal pattern of initial irrigation makes it possible to use the maximal packing height without considerable deterioration of mixture separation efficiency caused by formation of large-scale maldistribution of local mixture flows within the packing. Periodic packing irrigation also allows destruction of large-scale structures of local flow maldistribution within the structured packing. This paper presents data obtained in experiments on Sulzer 500X structured packing with the diameter of 0.6 m and height of 2.2 m at periodic packing irrigation. The working liquid was R114/R21 mixture. The packing was irrigated by a liquid distributor with possibility of independent control of any of 123 drip points. The experiments were carried out under the conditions of total reflux (L/V = 1) and L/V = 1.65.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.