Abstract

The variation in micro-hardness (HV) within simulated large cavities (10 × 6 mm) filled in one increment with three bulk-fill resin-based composites (BF-RBC) was assessed by means of a universal hardness device. Modern blue and violet-blue light curing units (LCUs) were applied in three different positions, by rotating the LCU in 120° steps. The exposure distance was 3 mm. One center and two peripheral (4-mm apart from the center) HV line profiles were measured in 0.5-mm steps at 24 hours postpolymerization to calculate the depth of cure (DOC). Incident light, irradiance, and spectral distribution were recorded. A multivariate analysis (general linear model) assessed the effect of the varied parameters as well as their interaction terms on HV and DOC. The effect of LCU rotation was not significant ( p=0.109). The DOC varied between 3.46 mm and 5.50 mm and was more strongly influenced by the BF-RBC ( p<0.001, ηP2=0.774), followed by the width of specimen ( p<0.001, ηP2=0.554), while the influence of the LCU was very low ( p<0.06, ηP2=0.070). Whether a BF-RBC filling is cured as well in the periphery as in the center depends more on the material than on the curing unit used.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.