Abstract
Abstract In two separate experiments we investigated the effects of different types of suture material and patterns on wound healing in rainbow trout Oncorhynchus mykiss with and without transmitter implants. We used absorbable and nonabsorbable monofilament and braided silk sutures in simple interrupted and vertical mattress patterns to close 3-cm incisions on rainbow trout. Braided silk sutures and vertical mattress suture patterns caused significantly more tissue inflammation (P < 0.05) as shown by macroscopic analysis. However, there were no significant differences in the histology or strength of the wounds related to the type of suture material or the type of suture pattern used. Dummy radio transmitters compounded the inflammatory effect silk had on healing incisions compared with inflammation without transmitters.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.