Abstract

Using disulphine blue, sheep tibial cortex perfusion was decreased by subperiosteal stripping but not by extraperiosteal exposure. Semitubular plates applied with either low (20 kp) force, sufficient for extraosseous vascular occlusion, or high (200 kp) force, similar to that used clinically, both produced significant ischemia beneath the plate. In contrast, the dynamic compression plate produced significantly greater ischemia only with the higher force.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.