Abstract
Osteoconductivity of titanium-alloy implants may be improved when surface-modified by calcium ion (Ca 2+) implantation. We studied the effects of Ca 2+ implantation on osseointegration of a grit-blasted titanium-alloy stem using a canine total hip arthroplasty model. Fifteen dogs underwent bilateral hip arthroplasties and were sacrificed at 1, 6, and 12 months postoperatively. The hip components were evaluated by radiographic, qualitative, and quantitative histology methods. Radiographically and histologically, both Ca 2+-implanted and non—Ca 2+-implanted stems were well integrated. Ca 2+-implanted stems had greater new bone apposition than non—Ca 2+-implanted stems, although the difference was significant only at 1 month (15.8% ± 3.5% of the implant perimeter for non—Ca 2+-implanted, 25.4% ± 4.7% for Ca 2+-implanted, P<.05). This result could be related to chronological decrease of the dissolution rate of calcium ions from Ca 2+-implanted surface. Although further improvement of the Ca 2+ implantation technique for a sustained osteoconductive effect is necessary, Ca 2+ implantation may be beneficial for early fixation of titanium-alloy implants.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.