Abstract

To examine whether exposure to the Spirometry Fundamentals™ CD-ROM results in improved quality of spirometry testing in primary care. Spirometry tests performed in 20 intervention and 19 control practices were analysed using American Thoracic Society grades A and B for 'passing' and grades C, D and F for 'failing'. Intervention effects on spirometry quality were assessed using random effects multivariate logistic regression. Adjusted analyses revealed no intervention effect. The likelihood of passing tests was higher in paediatrics-only practices (adjusted odds ratio (AOR) 2.60, 95% confidence interval (CI) 1.32 to 5.12; p=0.01). Hospital or university-based clinics had a lower performance than private or community-based practices in unadjusted analysis (7% vs. 22% passing tests; p=0.05). However, this relationship was not significant in adjusted analyses. Spirometry Fundamentals™ is insufficient to improve the quality of spirometry in primary care, suggesting the need for more comprehensive multifaceted training resources.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.