Abstract

A blackbody cavity is developed for continuously measuring the temperature of molten steel, which consists of a cylindrical outer tube with a flat bottom, a coaxial inner tube, and an aperture diaphragm. The ray-tracing approach based on the Monte Carlo method was applied to calculate the effective emissivity for the isothermal cavity with the diffuse walls. And the dependences of the effective emissivity on the inner tube relative length were calculated for various inner tube radii, outer tube lengths, and wall emissivities. Results indicate that the effective emissivity usually has a maximum corresponding to the inner tube relative length, which can be explained by the impact of the inner tube relative length on the probability of the rays absorbed after two reflections. Thus, these results are helpful to the optimal design of the blackbody cavity.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.