Abstract
The ac breakdown performance of rod-plane air gaps in the presence of water streams has been explored. Experimental results show that the ac breakdown voltage of rod-plane short air gaps in the presence of a water stream is significantly lower than in the dry condition. In addition, the ac breakdown voltage of an air gap decreases with the increase of the water stream velocity, diameter and conductivity. The relative breakdown voltage of an air gap decreases with an increase of water stream velocity from 0.75 m/s to 1.79 m/s and nozzle diameter from 1.0 mm to 3.0 mm by 2.6% / 0.1 m/s and 0.8% / 0.1 mm, respectively. High speed images of the deformation of the water stream and the breakdown process of air gap are reported show that with the increase of the applied voltage, the critical break-up length and the size of main water droplets decrease. In addition, the effect of the electrical field on the break-up length of a water stream and the size of droplets are independent of the jet velocity.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
More From: IEEE Transactions on Dielectrics and Electrical Insulation
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.