Abstract
To assess tidal volume (Vt) and minute ventilation (MV) during cardiopulmonary resuscitation (CPR) with two different chest compressions techniques: two-finger (TFT) or two-thumb technique (TTT) in a neonatal model. Vt and MV were continuously measured during consecutive periods of resuscitation in an intubated manikin. Thirty participants performed the two compression techniques in a random order for 2-min periods while performing positive pressure ventilation using a T-piece resuscitator (TPR) or a self-inflating bag (SIB). Vt during CPR with TFT was significantly higher than TTT with either TPR: 44.9 ± 4.3 vs 39.2 ± 5.4 ml (p < 0.001) or SIB: 39.2 ± 5.7 vs 35.6 ± 6.5 ml (p < 0.023). Similarly MV was significantly higher in TFT than TTT with either mode: 1346 ± 130 vs 1175 ± 162 ml/min, respectively, with TPR (p < 0.001) and 1177 ± 170 vs 1069 ± 196 ml/min with SIB (p < 0.03). Chest compressions during CPR using the TFT achieved higher Vt and MV than TTT in this model of neonatal resuscitation.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
More From: Journal of perinatology : official journal of the California Perinatal Association
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.