Abstract

Experiments were performed to measure the effect of trace metals on a vital function of the alveolar macrophage (AM), phagocytosis. Since certain trace metals were found to reduce the viability of AMs, a technique was developed to permit examination of live cells only for phagocytosis. Evidence is presented that Ni(2+) selectively altered the phagocytic activity of AMs at concentrations lower than those which caused cell death. It is further shown that a level of VO(3) (-) that caused extensive lysis and death did not reduce phagocytosis in surviving cells. The effects of Cd(2+), Cr(3+), and Mn(2+) on AMs were also examined.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.