Abstract
Soft metal gaskets (indium and silver) were used to reduce contact resistance between the wire and the electrode in an aluminum wire Z pinch by more than an order of magnitude over the best weighted contact case. Clamping a gasket over a Z-pinch wire compresses the wire to the electrode with a greater normal force than possible with wire weights. Average contact resistance was reduced from the range of 100-3000 Omega (depending on wire weight mass) to 1-10 Omega with soft metal gaskets. Single wire experiments (13 microm Al 5056) on a 16 kA, 100 kV Marx bank showed an increase in light emission (97%) and emission volume (100%) of the plasma for the reduced contact resistance cases. The measured increases in plasma volume and light emission indicate greater energy deposition in the ablated wire. Additionally, dual-wire experiments showed plasma edge effects were significantly decreased in the soft metal gasket contact case. The average height of the edge effects was reduced by 51% and the width of the edge effects was increased by 40%, thus the gasket contact case provided greater axial uniformity in the plasma expansion profile of an individual wire.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.